Sun StorEdge 3000 Family RAID Firmware 4.2x User's Guide
|
  
|
This appendix lists the firmware parameter settings for Sun StorEdge 3510 FC arrays, Sun StorEdge 3511 SATA arrays, Sun StorEdge 3310 SCSI arrays, and Sun StorEdge 3320 SCSI arrays. You can fine-tune your array by making changes to these settings. It also lists the parameter defaults that you should not change unless advised to do so by technical support.
Topics covered include:
Introducing Default Parameters
Although the factory defaults provide optimized controller operation, you might want to fine-tune your array through minor modifications to the following parameters listed.
Some parameters can be changed only at the initial array configuration; other parameters can be changed at any time. Note the listing of parameters defaults that should not be changed unless directed by technical support.
Basic Default Parameters
These parameters are the primary settings for each array.
TABLE D-1 Logical Drive Parameters (View and Edit Logical Drives)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Create Logical Drives
|
1 RAID 0 per array.
No spares per array.
1-32 drives per array.
|
1 RAID 0 per array.
No spares per array.
1-16 drives per array.
|
|
Change a Logical Drive Controller Assignment
|
Primary.
|
|
Secondary.
|
TABLE D-2 Logical Volume Parameters (View and Edit Logical Volumes)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Create a Logical Volume
|
Primary controller.
|
Primary controller.
|
Secondary.
|
TABLE D-3 Host LUN Parameters (View and Edit Host LUNs)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Host LUN IDs
|
16 IDs per channel maximum in loop mode; 1 ID per channel in point-to-point mode.
Channel 0 ID 40 - primary.
Channel 1 ID 42 - secondary.
Channel 4 ID 44 - primary.
Channel 5 ID 46 - secondary.
|
2 IDs per channel maximum.
Channel 1 ID 0- primary.
Channel 1 ID NA- secondary.
Channel 3 ID NA- primary.
Channel 3 ID 1- secondary.
|
TABLE D-4 Drive Parameters (View and Edit Drives)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
FC Drive ID Switch Settings
|
0
|
0
|
0-7
|
TABLE D-5 Channel Parameters (View and Edit Channels)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Host Channel Settings
|
0, 1, 4, 5 Host Channels.
|
1, 3 Host Channels.
|
Vary by product.
|
Drive Channel Settings
|
2 and 3
|
0 and 2
|
Vary by product.
|
Sync Transfer Clock
|
80 MHz
|
80 MHz
|
Do not change this parameter.
2.5 MHz to 80 MHz and Async.
|
Wide Transfer
|
Enabled.
|
Enabled.
|
Do not change this parameter.
Enabled.
Disabled.
|
Parity Check
|
Enabled.
|
Enabled.
|
Do not change this parameter.
Disabled.
Enabled.
|
Default Configuration Parameters
The parameters in the following tables can be set using the View and Edit Configuration Parameters menu:
The most important parameters to review are the caching parameters, which impact the block size and optimization performance. Many parameters are optional or unused, depending on the applicable product.
The next three tables show the default settings and range of available values for various communication parameter settings:
TABLE D-6 Communication Parameters > RS-232 Port Configuration
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Baud Rate
|
38,400
|
38,400
|
9,600, 19,200, 4,800, 2,400, 38,400
|
Data Routing
|
Direct to Port.
|
Direct to Port.
|
Point-to-Point (PPP).
Direct to Port.
|
Terminal Emulation
|
Enabled.
|
Enabled.
|
Disabled.
Enabled.
|
TABLE D-7 Communication Parameter > Internet Protocol (TCP/IP)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
TCP/IP Addresses
|
DHCP Client
|
DHCP Client
|
DHCP client, RARP client, or type IP address, netmask, and gateway
|
TABLE D-8 Communication Parameters > Network Protocol Support
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Telnet
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
HTTP
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
HTTPS
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
FTP
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
SSH
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
PriAgent
|
Enabled
|
Enabled
|
Do not change this setting
Enabled
Disabled
|
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
SNMP
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
DHCP
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
Ping
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
TABLE D-9 Communication Parameter > Telnet Inactivity Timeout Time
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Telnet Inactivity Timeout Time
|
Disabled.
|
Disabled.
|
Disabled or 60 seconds through 2700 seconds
|
TABLE D-10 Caching Parameters
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Write-Back Cache
|
Enabled.
|
Enabled.
|
Disabled.
Enabled.
|
Optimization for Random/Sequential
|
Sequential.
|
Sequential.
|
Sequential or Random
|
Periodic Cache Flush Time
|
Disabled.
|
Disabled.
|
Disabled.
Continuous Sync
1/2 minute
1 minute
2 minutes
5 minutes
10 minutes
|
TABLE D-11 Peripheral Device Type Parameters
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Peripheral Device Type
|
Enclosure Services Device.
|
Enclosure Services Device.
|
No Device Present.
Direct-Access Device.
Sequential-Access Device.
Processor Device.
CD-ROM Device.
Scanner Device.
MO Device.
Storage Array Controller Device.
Enclosure Services Device.
Unknown Device.
|
Peripheral Device Type Qualifier
|
Connected.
|
Connected.
|
Disconnected.
Connected.
|
Device Supports Removable Media
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
LUN Applicability
|
Undefined LUN-0s Only.
|
|
Disabled.
|
TABLE D-12 Host-Side and Drive-Side Parameters
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Host-side Parameters
|
Maximum Queued I/O Count
|
1024
|
1024
|
Auto, or 1-1024
|
LUNs per Host SCSI ID
|
32 (FC)
|
32
|
1 to 32
|
Maximum Number of Concurrent Host-LUN Connections
|
1024
|
128
|
1 to 1024
|
Number of Tags Reserved for Each Host-LUN Connection
|
1024
|
32
|
1 to 1024 (FC)
1 to 256 (SCSI)
|
In-band Management
|
Enabled
|
Enabled
|
Enabled.
Disabled.
|
Host-side Parameters > Host Cylinder/ Head/ Sector Mapping Parameters
|
Sector Ranges
|
Variable
|
Variable
|
32, 64, 127, 255, Variable sectors.
|
Head Ranges
|
64
|
64
|
64, 127, 255, Variable heads.
|
Cylinder Ranges
|
< 65536
|
< 65536
|
1024, 32768, 65536, Variable cylinders.
|
Host-side Parameters > Fibre Connection Option
|
|
Fibre Connection Option
|
Loop only
|
N/A
|
FC Range of Values:
Point to point only
Loop only
|
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Drive-side Parameters
|
Drive Motor Spin-Up
|
Disabled.
|
Disabled.
|
Do not change this parameter.
Enabled.
Disabled.
|
Disk Access Delay Time
|
15 seconds.
|
15 seconds.
|
Do not change this parameter.
None to 75 seconds.
|
Drive I/O Timeout
|
30 seconds.
|
30 seconds.
|
500 milliseconds to 30 seconds.
|
Queue Depth
|
32
|
32
|
32
|
Maximum Tag Count
|
32 (FC)
4 (SATA)
|
32
|
1-256 or Disabled.
|
Periodic Drive Check Time
|
30 seconds.
|
30 seconds.
|
1/2 to 30 seconds.
|
Periodic SAF-TE and SES Check Time
|
30 seconds.
|
30 seconds.
|
Disabled to 60 seconds.
|
Periodic Auto-Detect Failure Drive Swap Check Time
|
Disabled.
|
Disabled.
|
5 to 60 seconds.
Disabled.
|
Drive Predictable Failure Mode (SMART)
|
Detect and Clone + Replace.
|
Detect and Clone + Replace.
|
Detect Only
Detect and Perpetual Clone.
Detect and Clone + Replace.
|
Auto-Assign Global Spare Drive
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
Media Scan at Power-Up
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
TABLE D-13 Other Configuration Parameters
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Disk Array Parameters
|
Rebuild Priority
|
Low.
|
Low.
|
Normal, Improved, High, Low.
|
Verification on Writes
|
Disabled.
|
Disabled.
|
On LD Initialization Writes Disabled.
On LD Rebuild Writes Disabled.
On Normal Drive Writes Disabled.
|
Mixed Drive Support
|
Enabled.
|
N/A
|
Enabled (FC and SATA Only)
Disabled (FC and SATA Only)
|
Redundant Controller Parameters
|
Cache Synchronization on Write-Through
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
Controller Parameters
|
Controller Name
|
Not Set.
|
Not Set.
|
Type a name.
|
Password Validation Timeout
|
Always Check.
|
Always Check.
|
Disable, 1, 2, or 5 minutes.
|
Controller Unique Identifier
|
Automatically set by the SAF-TE or SES device.
|
Automatically set by the SAF-TE or SES device.
|
Type a value.
|
Default Peripheral Device Parameters
The following peripheral device parameters are available.
TABLE D-14 Peripheral Device Type Parameters (View and Edit Peripheral Devices)
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Set Peripheral Device Entry
|
Redundant Controller
|
Primary.
|
Primary.
|
Force primary controller failure.
Force secondary controller failure.
|
UPS Status
|
Disabled.
|
Disabled.
|
Enabled.
Disabled.
|
Set Peripheral Device Entry > Event Trigger Operations
|
Controller Failure
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
BBU Low or Failed
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
Power Supply Failed
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
Fan Failure
|
Enabled.
|
Enabled.
|
Enabled.
Disabled.
|
Temperature exceeds threshold
|
Shutdown Period: 30 minutes.
|
Shutdown Period: 30 minutes.
|
Disabled.
Enabled.
Shutdown periods from two minutes to one hour.
|
Controller Peripheral Device Configuration > Voltage and Temperature Parameters
|
Upper Trigger Threshold for +3.3V Event
|
Default (3.6V).
|
Default (3.6V).
|
Disable, 3.4V-3.9V.
|
Lower Trigger Threshold for +3.3V Event
|
Default (2.9V).
|
Default (2.9V).
|
Disable, 2.6V-3.2V.
|
Upper Trigger Threshold for +5V Event
|
Default (5.5V).
|
Default (5.5V).
|
Disable, 5.2V-6.0V.
|
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Lower Trigger Threshold for +5V Event
|
Default (4.5V).
|
Default (4.5V).
|
Disable, 4.0V-4.8V.
|
Upper Trigger Threshold for +12V Event
|
Default (13.2V).
|
Default (13.2V).
|
Disable, 12.5V-14.4V.
|
Lower Trigger Threshold for +12V Event
|
Default (10.8V).
|
Default (10.8V).
|
Disable, 9.6V-11.5V.
|
Upper Trigger Threshold for CPU Temperature Events
|
Default 95° C.
|
Default 95° C.
|
Disable, 50-100° C.
|
Lower Trigger Threshold for CPU Temperature Events
|
Default 0° C.
|
Default 0° C.
|
Disable, 0-20° C.
|
Upper Trigger Threshold for Board Temperature Events
|
Default 85° C.
|
Default 85° C.
|
Disable, 50-100° C.
|
Lower Trigger Threshold for Board Temperature Events
|
Default 0° C.
|
Default 0° C.
|
Disable, 0-20° C.
|
Default System Functions
The following system function parameters are available.
TABLE D-15 System Function Parameters
User-Defined Parameter
|
FC and SATA Default Setting
|
SCSI Default Setting
|
Range of Values
|
Mute Beeper
|
No.
|
No.
|
Yes.
No.
|
Change Password
|
No.
|
No.
|
Type a password.
No.
|
Reset Controller
|
No.
|
No.
|
Yes.
No.
|
Shutdown controller (reserved)
|
No.
|
No.
|
Yes.
No.
|
Controller Maintenance
|
Restore NVRAM from disks
|
No.
|
No.
|
Yes.
No.
|
Save NVRAM to disks
|
No.
|
No.
|
Yes.
No.
|
Parameter Defaults That Must Not Change
Do not change the following default parameters unless directed to do so by Technical Support.
TABLE D-16 Default Parameters That Must Not Change (unless directed to do so by Technical Support)
Parameter
|
Default Setting
|
Fault Management
|
|
SDRAM ECC
|
Enabled.
|
SCSI Parameters
|
|
Data Transfer Rate (sync transfer clock)
|
80 MHz.
|
Wide Transfer
|
Enabled.
|
Parity Check
|
Enabled.
|
Spin-Up Parameters
|
|
SCSI Motor Spin-Up
|
Disabled.
|
SCSI Reset at Power-Up
|
Enabled.
|
Disk Access Delay Time
|
15 (none to 75 seconds).
|
Network Protocol Support
|
|
PriAgent
|
Enabled.
|
Sun StorEdge 3000 Family RAID Firmware 4.2x User's Guide
|
817-3711-18
|
  
|