Advanced Lights Out Management (ALOM) CMT v1.4 Guide
|
    |
Advanced Lights Out Management (ALOM) CMT v1.4 Guide
819-7991-10
Tables
Preface
1. Advanced Lights Out Manager (ALOM) CMT Introduction
ALOM CMT Features
What ALOM CMT Monitors
Using ALOM CMT
Fault and Failure Terminology
Faulty State
Failed State
Platform-Specific Information
2. Security Guidelines
Securing the System Controller
Selecting a Remote Connection Type
Enabling Secure Shell
Instructions to Enable SSH
Features Not Supported by SSH
Changing SSH Host Keys
Solaris Operating System Security
3. Configuring ALOM CMT
ALOM CMT Configuration Steps
Planning Your ALOM CMT Configuration
Choosing System Conroller Communication Ports
Serial Management Port

To Connect to the Serial Port
Network Management (Ethernet) Port
Default DHCP Connection
Client Identifier (clientid)
Default Password
Steps to Use DHCP on a New Out-of-Box System
Configuration Worksheet
Configuration Variable Worksheet
Related Information
Configuring Your Network
Configuring Your Network Using DHCP
Configuring Your Network Manually
Configuring Email Alerts
Setting Up ALOM CMT
Customizing the ALOM CMT Software
Related Information
4. Common Tasks
Connecting to ALOM CMT
Logging In To ALOM CMT Accounts

To Log In To ALOM CMT
Related Information
Rebooting ALOM CMT

To Reboot ALOM CMT
Switching Between the System Console and ALOM CMT

To Switch Between the System Console and ALOM CMT
System Console Output at Power On
Displaying Your ALOM CMT Version

To Display Your ALOM CMT Version
Controlling the Locator LED

To Control the Locator LED
Powering On and Off the Host Server

To Power the Host Server On and Off
Resetting the Host Server

To Reset the Host Server
Viewing Environmental Information About the Server

To View Environmental Information
Reconfiguring ALOM CMT Diagnostic Parameters

To Run the setupsc Script
Reconfiguring ALOM CMT to Use the Ethernet Port

To Configure the Network Interface Variables

To Reboot ALOM CMT
Set the Network Interface Variables Using the setsc Command
Adding ALOM CMT User Accounts

To Add an ALOM CMT User Account

To View Permissions and Password Status of Users
Removing ALOM CMT User Accounts

To Remove an ALOM CMT User Account From the sc> Prompt
Changing the Password on an Account

To Change Your ALOM CMT Password

To Change the ALOM CMT Password for Another User
Sending and Receiving Alert Messages

To Set Up Email Alerts
Receiving Alerts From ALOM CMT
5. ALOM CMT Fault Management Tasks
Fault Information Sources
Getting Knowledge Articles for Managing Faults

To Get the Appropriate Knowledge Article
6. Using Simple Network Management Protocol (SNMP)
SNMP Overview
How SNMP Works
SNMP Management Information Base Files
MIBs Integration
SNMP Messages
ALOM CMT and SNMP
Integrating the MIBs
Adding Your Server to Your SNMP Environment
Configuring Receipt of SNMP Traps
7. Using the ALOM CMT Command Shell
ALOM CMT Command Shell Overview
Entering Command Options
Related Information
ALOM CMT Shell Commands
Related Information
ALOM CMT Shell Command Descriptions
bootmode

To Use the bootmode Command

To View bootmode Settings
bootmode Command Options
Related Information
break

To Use the break Command
break Command Options
Related Information
clearasrdb

To Use the clearasrdb Command
clearfault
console

To Use the console Command
console Command Option
Related Information
consolehistory

To Use the consolehistory Command
consolehistory Command Options
Related Information
disablecomponent

To Use the disablecomponent Command
enablecomponent

To Use the enablecomponent Command
flashupdate

To Use the flashupdate Command
flashupdate Command Options
Related Information
help

To Use the help Command
Related Information
logout

To Use the logout Command
Related Information
password

To Use the password Command
Password Restrictions
Related Information
powercycle

To Use the powercycle Command
poweroff

To Use the poweroff Command
poweroff Command Options
Related Information
poweron

To Use the poweron Command
poweron Command Options
Related Information
removefru

To Use the removefru Command
removefru Command Options
reset

To Use the reset Command
reset Command Options
Related Information
resetsc

To Use the resetsc Command
resetsc Command Options
Related Information
restartssh

To Use the restartssh Command
Command Options
Related Information
setdate

To Use the setdate Command
setdate Command Options
Related Information
setdefaults

To Use the setdefaults Command
setdefaults Command Options
Related Information
setfru

To Use the setfru Command
setkeyswitch

To Use the setkeyswitch Command
setkeyswitch Command Options
setlocator

To Use the setlocator Command
setlocator Command Options
Related Information
setsc

To Use the setsc Command
Related Information
setupsc

To Use the setupsc Command
Related Information
showcomponent

To Use the showcomponent Command
showdate

To Use the showdate Command
Related Information
showenvironment

To Use the showenvironment Command
Related Information
showfaults

To Use the showfaults Command
showfru
showfru Command Options

To Use the showfru Command
Related Information
showhost

To Use the showhost Command
showkeyswitch

To Use the showkeyswitch Command
showlocator

To Use the showlocator Command
Related Information
showlogs

To Use the showlogs Command
showlogs Command Options
Related Information
shownetwork

To Use the shownetwork Command
shownetwork Command Option
Related Information
showplatform

To Use the showplatform Command
showsc

To Use the showsc Command
showsc Command Options
Related Information
showusers

To Use the showusers Command
showusers Command Option
ssh-keygen

To Use the ssh-keygen Command
ssh-keygen Command Options
Related Information
useradd

To Use the useradd Command
Related Information
userdel

To Use the userdel Command
userdel Command Option
Related Information
userpassword

To Use the userpassword Command
Password Restrictions
Related Information
userperm
Permission Levels

To Use the userperm Command
Related Information
usershow

To Use the usershow Command
Related Information
8. Using ALOM CMT Configuration Variables
ALOM CMT Configuration Variables Overview

To Use Configuration Variables in the ALOM CMT Command Shell
Serial Management Port Variables
Related Information
Network Interface Variables
Related Information
Network Management and Notification Variables
Related Information
System User Variables
Related Information
Diagnostic Control Variables
Related Information
Descriptions of Configuration Variables
diag_level

To Use the setsc Command to Change the diag_level Variable

To Use the setupsc Command to Change the diag_level Variable
diag_mode

To Use the setsc Command to Change the diag_mode Variable

To Use the setupsc Command to Change the diag_mode Variable
diag_trigger

To Use the setsc Command to Change the diag_trigger Variable

To Use the setupsc Command to Change the diag_trigger Variable
diag_verbosity

To Use the setsc Command to Change the diag_verbosity Variable

To Use the setupsc Command to Change the diag_verbosity Variable
if_connection

To Use the setsc Command to Set the if-connection Variable
Related Information
if_emailalerts

To Use the setupsc Command to Set the if_emailalerts Variable

To Use the setsc Command to Change the if_emailalerts Variable
if_network

To Use the setupsc Command to Set the if_network Variable

To Use the setsc Command to Change the if_network Variable
if_snmp

To Use the setupsc Command to Set the if_snmp Variable

To Use the setsc Command to Change the if_snmp Variable
mgt_mailalert

To Use the setupsc Command to Set the mgt_mailalert Variable

To Use the setsc Command to Change the mgt_mailalert Variable
Related Information
mgt_mailhost

To Use the setupsc Command to Set the mgt_mailhost Variable

To Use the setsc Command to Change the mgt_mailhost Variable
Related Information
mgt_snmptraps

To Use the setupsc Command to Set the mgt_snmptraps Variable

To Use the setsc Command to Change the mgt_snmptraps Variable
Related Information
mgt_traphost

To Use the setupsc Command to Set the mgt_traphost Variable

To Use the setsc Command to Change the mgt_traphost Variable
netsc_dhcp
Related Information
netsc_enetaddr
Related Information
netsc_ipaddr
Related Information
netsc_ipgateway
Related Information
netsc_ipnetmask
Related Information
sc_backupuserdata

To Use the setsc Command to Change the sc_backupuserdata Variable
sc_clieventlevel
Related Information
sc_cliprompt

To Use the setsc Command to Change the sc_cliprompt Variable
Related Information
sc_clitimeout
Related Information
sc_clipasswdecho
Related Information
sc_customerinfo
Related Information
sc_escapechars
Related Information
sc_powerondelay
Related Information
sc_powerstatememory
Related Information
ser_baudrate
Related Information
ser_data
Related Information
ser_parity
Related Information
ser_stopbits
Related Information
sys_autorestart
sys_autorunonerror
sys_eventlevel
sys_enetaddr
Related Information
A. Troubleshooting
Troubleshooting ALOM CMT Problems
Using ALOM CMT to Troubleshoot Server Problems
System Console Write Lock
ALOM CMT Shell Error Messages
Usage Errors
General Errors
CLI Messages Regarding FRU State
Related Information
Recovering ALOM CMT Passwords

To Recover Your ALOM CMT Passwords:
B. ALOM CMT Event Messages
Event Message Overview
Event Severity Levels
Event Messages
Startup Event Messages
SCC PROM Event Messages
System Controller Usage Event Messages
Environmental Monitoring Event Messages
Host Monitoring Event Messages
Index
Advanced Lights Out Management (ALOM) CMT v1.4 Guide
|
819-7991-10
|
    |
Copyright © 2007, Sun Microsystems, Inc. All Rights Reserved.