Hi,

The observedobject property should follow the exact naming convention.
But observedmbean property could be used to just specify the mbean name
and that would inturn have the object-name. This is an ease-of-use property.

HTH,
Shalini.

jsexton0 wrote:
> Hello -
>
> I found this follow-up blog post that completely explains the problem I had.
>
> http://blogs.sun.com/technical/entry/management_rules_observedmbean_property
>
> It's all working now, by using "observedmbean" instead of "observedobject"
> in the rule. I don't fully understand the distinction between the two, or
> is it simply a problem with the admin GUI? I don't know. But
> "observedobject" seems to be problematic?
>
> Thanks
>
>
> sankara rao bhogi wrote:
>
>>
>> You mean Obeserved MBean's getFreeMemory() is not even called once? When
>> the action is invoked, can you print Notification object.
>>
>> This is implemented in terms of javax.management.monitor.GauageMonitor
>> and you can expect the following behavior:
>>
>> *
>>
>> A |GaugeMonitor|
>>
>> <http://java.sun.com/javase/6/docs/api/javax/management/monitor/GaugeMonitor.html>
>> observes attributes of numerical type. Each observed attribute has
>> an associated /high threshold/ and /low threshold/.
>>
>> When an observed attribute crosses the high threshold, if the
>> /notify high/ flag is true, then a notification is sent.
>> Subsequent crossings of the high threshold value will not trigger
>> further notifications until the gauge value becomes less than or
>> equal to the low threshold.
>>
>> When an observed attribute crosses the low threshold, if the
>> /notify low/ flag is true, then a notification is sent. Subsequent
>> crossings of the low threshold value will not trigger further
>> notifications until the gauge value becomes greater than or equal
>> to the high threshold.
>>
>> Typically, only one of the notify high and notify low flags is
>> set. The other threshold is used to provide a /hysteresis/
>> mechanism to avoid the repeated triggering of notifications when
>> an attribute makes small oscillations around the threshold value.
>>
>> A |GaugeMonitor| can operate in /difference mode/. In this mode,
>> the value compared against the high and low thresholds is the
>> difference between two successive observations of an attribute.
>>
>>
>> jsexton0 wrote:
>>
>>> Additional...
>>>
>>> The data source (observed) mbean is never called. Why? The action is
>>> called once when the rule is activated. No error messages logged...
>>> I am basing this on an example found here:
>>>
>>> https://glassfish.dev.java.net/javaee5/selfmanagement/selfmanagement_example.html
>>>
>>> This is the way the rule get written:
>>>
>>> <management-rules enabled="true">
>>> <management-rule enabled="true" name="CMS_Memory_Rule">
>>> <event level="WARNING" record-event="true" type="monitor">
>>> <description>Memory Alert</description>
>>> <property name="observedobject"
>>> value="user:impl-class-name=com.iwsinc.cms.monitor.memory.CMSMemory,name=CMSMemoryMBean,server=server"/>
>>> <property name="observedattribute" value="FreeMemory"/>
>>> <property name="granularityperiod" value="1000"/>
>>> <property name="monitortype" value="gaugemonitor"/>
>>> <property name="differencemode" value="false"/>
>>> <property name="numbertype" value="long"/>
>>> <property name="lowthreshold" value="9000000"/>
>>> <property name="highthreshold" value="9700000"/>
>>> </event>
>>> <action action-mbean-name="CMSMemoryAction"/>
>>> <description>CMS_Memory_Rule</description>
>>> </management-rule>
>>> </management-rules>
>>>
>>> Any ideas?
>>> Thank you
>>>
>>>
>>> jsexton0 wrote:
>>>
>>>
>>>> Hello -
>>>>
>>>> I made a monitor-type self management rule. It functions, but it seems
>>>> to
>>>> only get called once when the rule is activated at start up. I added
>>>> some
>>>> logging so I should be able to see when the observedobject is used.
>>>>
>>>> What units is the granularityperiod parameter in? I figured it for
>>>> milliseconds and used 1000. Is it seconds?
>>>>
>>>> I've got no error messages or anything in the log. It just seems to
>>>> only
>>>> call the monitor object once.
>>>>
>>>> Thanks
>>>>
>>>>
>>>>
>>>>
>>>
>>>
>> ---------------------------------------------------------------------
>> To unsubscribe, e-mail: users-unsubscribe_at_glassfish.dev.java.net
>> For additional commands, e-mail: users-help_at_glassfish.dev.java.net
>>
>>
>>
>>
>
>