This appendix outlines the levels of software, firmware, and PTFs required for various library features and storage solutions. For the most up to date version requirements refer to the to the product specific documentation library on the Oracle Technical Network.
The table below lists the compatibility matrix for library management software. For the most up to date version requirements refer to the to the product specific documentation library on the Oracle Technical Network. Make sure the latest PTFs and PUTs are installed.
Table A-1 Library Software Compatibility Matrix
| Product | Required Version (or higher) |
|---|---|
|
7.1 or higher 7.3 or higher for Redundant Electronics 8.0 and above (T10000C, IPv6 support) |
|
|
7.0 and above |
|
|
6.1 or 6.2 |
|
|
LCM |
6.0 or 6.2 |
|
6.1 or 6.2 |
|
|
6.2 (VM only) Check for the latest PTF availability and compatibility. |
|
|
6.1 or 6.2 (includes VTCS and VTSS) |
|
|
1.0 or 2.0 |
The mainframe library management software requirements are listed in this section.
The table below lists the support for each level of ELS/HCS.
Table A-2 HSC/ELS PTF HLI Compatibility Level Support
| HSC/ELS Level | CompatLevel 20 or Below | Compat Level 21 | Compat Level 22 | Level 23 Minimum RE Support | Level 23 Enhanced RE Support | Level 23 Multi-RE Support | Level 23 Enhanced Partitioning |
|---|---|---|---|---|---|---|---|
|
6.2 (VM only) |
Level 21 PTF |
L1HA4UW |
L1H15DH |
L1H15H9 |
L1H15MF |
L1H168F |
L1H16EM |
|
7.0 (MVS only) |
Level 21 PTF |
L1H14UY |
L1H15DJ |
L1H15HB |
L1H15MH |
L1H168H |
L1H16EO |
|
7.1(MVS only) |
Included |
Included |
Included |
Included |
Included |
L1H168I |
L1H16EP |
Level 23 Minimum RE support
Allows a customer to connect to one SL8500 RE library in an ACS string.
The single connected RE library can be switched through the HSC switch command, but other libraries in a string can only be switched through SLConsole.
Level 23 Enhanced RE support
Allows a customer to connect to one SL8500 RE library in an ACS string.
All RE libraries can be switched through HSC switch command.
Can support up to 32 TPC/IP connections in an ACS string (LMU ADDR change).
Other enhancements include:
Dual TCP/IP support
Display ACS acs-id to display all RE connections
Auto CAP recovery after a switch
Support for 64 read in-transit cartridges during cartridge recovery
Level 23 Multi RE support
Allows a customer to connect to multiple SL8500 RE libraries in an ACS string up to 32 TCP/IP connections.
Includes the same functionality as the Enhanced RE support.
Level 23 Single SL8500 Enhanced Partitioning
Support for up to 8 partitions
Allows a customer to add or remove library resources (transports, cell magazines, and CAPs) of a partition
The following lists the requirements to support ACSLS:
ACSLS 7.1 or higher is required for support (with PTF-809236).
A TCP/IP connection is needed to connect the server to the library.
There are no required configuration changes for ACSLS to function.
For library firmware 6.x or later, ACSLS 7.3.1 or 8.0.2 is needed to insure ACSLS will automatically bring LSMs back online after a library outage.
For version specific requirements, refer to the ACSLS Product Information document for the specific version of ACSLS. This document can be found in the ACSLS product documentation library on the Oracle Technical Network.
Requirements for AS/400 to function as another type of management software to control the SL8500 library include:
RMLS/CSC must be at 1.3.0.
RMLS/CSC is the client component of ACSLS that runs on the AS/400. It performs the mounts, dismounts, enters, and ejects on the AS/400. This product integrates into the tape management systems for the AS/400. The tape management systems that RMLS/CSC integrates with are: IBM/BRMS, HelpSystems/RobotSave, and LXI/MMS.
OS/400 must be at V5R2.
OS/400 is the operating system that runs on an AS/400 and the iSeries platform. (iSeries is interchangeable with AS/400.)
ACSLS only supports TCP/IP communications to RMLS/CSC.
SNA (Systems Network Architecture) is not supported.
For the most current versions and compatibility refer to the independent software vendor website and documentation, or check with a Oracle representative and application vendor to make sure the selected solution is supported.
Table A-3 Independent Software Vendors
| Backup Application | Solaris | IBM AIX | HP-UX | Microsoft Windows | Linux Red Hat | Linux SUSE |
|---|---|---|---|---|---|---|
|
EMC NetWorker 7.3/7.4/7.5+ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Tivoli Storage Manager 5.5.1/6+ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Symantec Netbackup 6.0/6.5/7+ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
CA BrightStor 11.5 |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
|
CA ArcServe 16+ |
N/A |
N/A |
YN/A |
Yes |
N/A |
N/A |
|
HP Data Protector 5.5/6.0+ |
Yes |
N/A |
Yes |
Yes |
N/A |
N/A |
|
Quest NetVault 8.2+ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
SAM-FS 5.2 |
Yes |
N/A |
N/A |
N/A |
N/A |
N/A |
The table below lists supported ISVs.
Table A-4 Supported Independent Software Vendors
| ISV | Platform Supported |
|---|---|
|
Windows, Solaris , AIX, HP-UX |
|
|
Windows, Solaris |
|
|
Windows, Solaris, AIX, HP-UX, Linux |
|
|
Windows, Solaris, AIX, HP-UX, Linux |
|
|
Windows, Solaris, AIX, HP-UX, Linux |
The table below lists Tier 1 and Tier 2 partners.
Requirements for enhanced partitioning in the SL8500 library include:
SL Console at Version FRS_5.5x or higher
ACSLS HA 8
NCS (NearLine Control Solution) Version 6.2
VSM (Virtual Storage Module) all supported versions
Version 6.0 with PTF L1L00F6,
Version 6.1 (none),
Version 6.2 with PTF L1L00F7
Hosts without the latest level of software (ACSLS or HSC) or without the latest maintenance will not be able to manage a partitioned ACS online.
Always refer to My Oracle Support (MOS) for the latest versions of software and firmware and the Oracle Technology Network (OTN) for the latest versions of the documentation
|