To Apply Power

  1. Verify that the HBA is securely installed in the system.
  2. Verify that the correct fiber-optic cable is attached.
  3. Verify that the correct Ethernet cable is attached.
  4. Refer to your system installation or service manual to determine how to power on the system server module (blade).
  5. Observe the light-emitting diode (LED) status for the power-on self-test (POST) results as shown in the following table.

    The following table summarizes LED indicator combinations. Each FC port has a corresponding set of LEDs that provide a visual indication of the operating state.

    Green LED
    Yellow LED
    State
    On
    2 fast blinks
    2-Gb link rate - Normal operating state, link up
    On
    3 fast blinks
    4-Gb link rate - Normal operating state, link up
    On
    4 fast blinks
    8-Gb link rate - Normal operating state, link up
    Off
    Off
    Wake-up failure (failed board)
    Off
    On
    POST failure (failed board)
    Off
    Slow blink
    Wake-up failure monitor
    Off
    Fast blink
    Failure in POST
    Off
    Flashing
    POST processing in progress
    On
    Off
    Failure while functioning
    On
    On
    Failure while functioning
    Slow blink
    Off
    Normal - link down
    Slow blink
    On
    Not defined
    Slow blink
    Slow blink
    Offline for download
    Slow blink
    Fast blink
    Restricted offline mode (waiting for restart)
    Slow blink
    Flashing
    Restricted offline mode, test active
  6. Observe the LEDs status for the Ethernet connection as described in the following table.

    The following table summarizes LED indicator combinations. Each Ethernet port has a corresponding set of LEDs that provide a visual indication of the operating state.

    Green LED
    Green/Yellow LED
    State
    Blinks
    Off
    10-Mb link rate - Normal operating state, link up
    Blinks
    Green
    100-Mb link rate - Normal operating state, link up
    Blinks
    Yellow
    1-Gb link rate - Normal operating state, link up


    image:Image of the HBA LEDs and Attention button